Product Overview
Adopting TDLAS (Tunable Diode Laser Absorption Spectroscopy) technology, the LT-9000 in-situ direct-insertion laser oxygen analyzer can be directly installed on pipelines, reactors and other process equipment. Complicated sampling and pre-treatment are not required, enabling real-time online measurement of oxygen concentration. Featuring fast response and strong anti-interference capability, the instrument performs stably and reliably under harsh working conditions such as high temperature and heavy dust. It supports communication with DCS systems to realize data uploading, over-limit alarm and interlock function. It provides accurate and reliable measurement data for safety production, process optimization and explosion-proof monitoring in chemical, petrochemical, pharmaceutical and other industries.
Product Specification
| Parameter | Specification |
| Measured Gas | Oxygen (O₂) |
| Measurement Principle | Laser TDLAS |
| Measurement Range | 0–25% VOL |
| Sampling Method | Diffusion |
| Accuracy | ±2% FS |
| Repeatability | ±2% FS |
| Stability | ±3% FS/year |
| Resolution | 0.01% VOL |
| Response Time | ≤4s (T90) |
| Display | High-definition LCD |
| Alarm | LED visual alarm (explosion-proof audible & visual alarm optional) |
| Operation | Infrared remote controller |
| Power Supply | 24V DC (18–30V DC) |
| Power Consumption | ≤3W (heater off); ≤7W (heater on) |
| Output Signals | 4–20mA (3-wire), 3 sets of relay switch outputs, RS485 (Modbus); 4–20mA+HART optional |
| Electrical Connections | 3 ports: NPT3/4(F), NPT1/2(F), M25×1.5 (quantity and specs customizable) |
| Ambient Temperature | -40℃ ~ +70℃ |
| Relative Humidity | 0–99% RH, non-condensing |
| Sensor Service Life | ≥10 years |
| Explosion-proof Grade | Ex d IIC T6 Gb |
| Housing Material | Aluminum alloy / S316 stainless steel |
| Dimension | 310×124×132mm (W×H×D) |
| Weight | 5800g (S316 stainless steel version) |
Product feature
Advanced TDLAS oxygen analyzer designed for high-precision measurement and long-term reliability in harsh industrial environments.
TDLAS Technology
Adopts Tunable Diode Laser Absorption Spectroscopy for high accuracy, corrosion resistance, and a service life of ≥10 years.
Harsh Environment Adaptabilitys
Features intelligent heating and robust waterproof/dustproof protection, ideal for high-humidity and high-dust conditions.
Smart Self-Diagnosis
Built-in intelligent module self-inspection with automatic fault alarm ensures stable operation and easy maintenance.
User-Friendly Interface
Equipped with a high-definition LCD and bilingual (English/Chinese) menu, easily adjustable via infrared remote controller.

Application
- Petrochemical & Coal Chemical: Real-time oxygen monitoring for reactors, process pipelines, coal gasification and syngas systems, ensuring explosion protection and oxidation reaction control.
- Fine Chemical & Pharmaceutical: Residual oxygen monitoring in hydrogenation reactions, inert gas protection processes and sealed reactors.
- New Energy: Atmosphere oxygen control in production lines for lithium battery materials, silicon materials and carbon materials.
- Metallurgical Industry: Oxygen concentration measurement for heat treatment furnaces and protective atmosphere pipelines.
- Waste Incineration: Online oxygen analysis in incineration flue gas for combustion optimization and emission control.
- Food & Powder Processing: Inert gas protection for powder materials and oxygen monitoring in sealed reactors.
Why Choose our LT-9000 Laser Oxygen Analyzer?
- No complex sampling required: In-situ direct insertion installation eliminates the need for complicated pretreatment systems, while TDLAS technology delivers strong anti-interference performance and stable oxygen measurement even in high-temperature and dusty conditions.
- Built for chemical safety: CT6 explosion-proof design with DCS communication and interlock protection enables real-time monitoring to prevent explosion hazards in chemical processes.
- Low long-term maintenance: Sensor lifespan of over 10 years with built-in intelligent self-diagnosis significantly reduces ongoing maintenance costs.
- Fast response for process control: T90 response time ≤4s quickly captures oxygen concentration changes for precise control of reactors and incinerators.
- Flexible customization: Customizable housing material and port specifications with bilingual menu, suitable for petrochemical, new energy, and metallurgical applications.
FAQ
Q: What detection technology does the LT-9000 use?
A: TDLAS (Tunable Diode Laser Absorption Spectroscopy), highly resistant to water vapor and dust interference.
Q: What signal outputs are supported?
A: 4-20mA, RS485 Modbus, and relay outputs as standard; 4-20mA + HART is optional.
Q: What is the operating temperature range?
A: -40℃ to +70℃, with stable performance even in high-humidity environments.
Q: What housing materials are available?
A: Aluminum alloy and S316 stainless steel, suitable for different corrosive conditions.
Q: What alarm functions are included?
A: Standard LED visual alarm; explosion-proof audible & visual alarm with fault alert is optional.
Hot Tags: in-situ direct-insertion laser oxygen analyzer, China in-situ direct-insertion laser oxygen analyzer manufacturers, suppliers, factory, Gas Dew Point Online Analyzer, Industrial online gas dew point meter, Integrated TPF Monitor, Natural gas online gas dew point meter, Pipeline gas dew point meter, Temperature Pressure Flow Combined