Explosion Proof Online Gas Detector

Explosion Proof Online Gas Detector
Details:
The GD200-W/M-D is a rugged, explosion-proof multi-gas monitor designed for continuous safety monitoring in hazardous industrial environments. It simultaneously detects 1 to 4 gases—including combustibles (e.g., CH₄, LEL), toxic gases (e.g., H₂S, CO, O₂, NH₃), and other target vapors—using field-proven electrochemical, catalytic, or infrared sensor technologies.
Send Inquiry
Download
Description
Technical Parameters

Product Overview

 

 

product-800-800

The GD200-W/M-D is a rugged, explosion-proof multi-gas monitor designed for continuous safety monitoring in hazardous industrial environments. It simultaneously detects 1 to 4 gases-including combustibles (e.g., CH₄, LEL), toxic gases (e.g., H₂S, CO, O₂, NH₃), and other target vapors-using field-proven electrochemical, catalytic, or infrared sensor technologies. With support for over 50 pre-calibrated, plug-and-play sensor modules, the system enables flexible configuration and rapid deployment across diverse applications.

Housed in a die-cast aluminum enclosure rated Ex d IIC T6 and IP66, the detector delivers stable, temperature-compensated readings with high sensitivity and reliable performance-even under extreme conditions (–30°C to +65°C, up to 95% RH). Its robust design meets the demands of confined space entry, process area monitoring, and critical infrastructure protection, where safety, durability, and ease of maintenance are non-negotiable.

⚠️ Note: Sensor replacement requires zero/span verification per safety best practices. Full calibration is recommended after module change.

 

 
 
Key Features

High-Reliability Sensing Technology

Utilizes field-proven electrochemical, catalytic bead, and infrared sensors from leading global suppliers-delivering fast response (T90 ≤30 s) and stable measurement accuracy (±3% FS typical).

Modular, Flexible Gas Configuration

Supports 1 to 4 gases in any combination via hot-swappable sensor modules. Each module is pre-calibrated at the factory to minimize setup time-though zero/span verification is recommended after replacement per safety best practices.

Seamless System Integration

Standard RS-485 output with Modbus RTU protocol and two independent relay outputs (for alarms or control) enable direct connection to PLCs, DCS, or safety systems. Optional 4–20 mA output available for analog integration.

Safe, Non-Contact Operation via Infrared Remote

Perform configuration, calibration, and diagnostics without opening the enclosure-critical in hazardous areas. Supports multi-point calibration (up to 4 levels) for enhanced accuracy across the measurement range.

Ruggedized for Harsh Industrial Environments

Die-cast aluminum housing certified to Ex d IIC T6 (or IIB T6, as applicable) and rated IP66-fully protected against dust, water jets, and explosive atmospheres. Operates reliably from –30°C to +65°C at up to 95% RH.

Note

Full calibration after sensor replacement is advised to ensure compliance with occupational safety standards (e.g., OSHA, ISO 10156).

 

Technical parameter

 

 

Category

Parameter

Display Mode

Color LCD screen

Detection Method

- Diffuse (standard)
- Pump suction (optional, via external accessory)

Zero Drift

≤ ±1% F.S. / year

Response Time (T₉₀)

≤ 30 s

Recovery Time

≤ 60 s

Operating Pressure Range

86–106 kPa (standard atmospheric pressure; not suitable for pressurized lines)

Alarm Method

Audible and visual alarm (sound + alarm light); optional

Installation Method

Wall-mounted

Indication Error

≤ ±3% F.S.

Protection Rating

IP66 (dust-tight and protected against powerful water jets)

Signal Output

- 4-wire RS-485 (standard)
- 4–20 mA analog output (optional)

Usage Environment

- Temperature: –30 °C to +65 °C
- Humidity: 0–95% RH (non-condensing)

 

Core Application Scenarios
 

Confined Space Entry & Underground Operations

In enclosed environments such as tanks, silos, sewers, utility tunnels, and underground vaults, oxygen deficiency, toxic gas accumulation (e.g., H₂S, CO), or combustible gas leaks pose immediate life-threatening risks. The SafeGuard X4 enables real-time, multi-gas monitoring during entry and work procedures-ensuring compliance with OSHA/GB standards for confined space safety. Its IP66 rating and infrared remote control allow safe operation without opening the enclosure in hazardous zones.

Oil, Gas & Chemical Processing Facilities

From wellheads and compressor stations to chemical storage yards and loading terminals, continuous monitoring of methane (LEL), H₂S, CO, and oxygen is critical for personnel safety and process integrity. The detector's Ex d IIC T6 certification, modular sensor design, and Modbus output support seamless integration into plant-wide safety systems-providing early warning of leaks, ventilation failures, or off-spec gas conditions.

Municipal Infrastructure & Utility Tunnels

Gas hazards in urban underground networks-including natural gas distribution lines, wastewater treatment plants, and utility corridors-require reliable, low-maintenance monitoring. The unit's rugged IP66/Ex d design withstands high humidity, dust, and temperature swings, while its wall-mounted form factor and 4–20 mA/RS485 outputs enable long-term deployment in remote or unattended locations such as pump stations and pipe galleries.

 

Why choose our explosion-proof four in one gas detector?

 

 

 

Reliable Performance Where It Matters Most

Equipped with high-stability sensors, the detector delivers a fast T90 response of ≤30 seconds and typical measurement accuracy within ±3% of full scale-ensuring timely alerts for combustible, toxic, and oxygen-deficient atmospheres in safety-critical environments.

 

Minimized Downtime, Simplified Maintenance

Hot-swappable sensor modules allow rapid replacement in the field. While each module is factory pre-calibrated to reduce setup time, zero/span verification is supported via infrared remote control-enabling safe, non-contact calibration without opening the enclosure, even in Zone 1 hazardous areas.

 

Built for Seamless System Integration

Standard RS-485 (Modbus RTU) and two programmable relay outputs provide direct connectivity to fire panels, PLCs, or central monitoring systems. Optional 4–20 mA output, integrated pump (for active sampling), and audible/visual alarms offer flexibility for diverse site requirements.

 

Engineered for Extreme Conditions

Housed in a rugged die-cast aluminum enclosure certified to Ex d IIC T6 (or IIB T6 as applicable) and rated IP66, the unit operates reliably in temperatures from –30°C to +65°C and humidity up to 95% RH-resisting dust, water jets, and explosive gas atmospheres.

 

Quick to Install, Easy to Deploy

Compact and lightweight (<1.8 kg), the detector features a standard wall-mount design with M20×1.5 cable glands and a wide DC 12–30 V power input, simplifying installation in new or existing facilities-even in space-constrained locations.

 

Proven Across High-Risk Industries

Trusted in applications where safety cannot be compromised:

Confined space entry (tanks, sewers, vaults)

Oil & gas production, chemical storage, and loading operations

Municipal utility tunnels, wastewater plants, and power generation sites

Designed not just to detect-but to protect.

Note: Sensor replacement requires verification of zero and span points per occupational safety guidelines. Full calibration ensures compliance with local regulations.

 

FAQ

 

 

Q1: How many gases can the detector monitor at the same time?

A: The unit supports 1 to 4 gases simultaneously, with flexible combinations of combustible (LEL), toxic (e.g., H₂S, CO, NH₃), and oxygen sensors. Over 50 plug-and-play sensor modules are available for configuration.

Q2: Is sensor replacement straightforward in the field?

A: Yes. Sensors are designed as hot-swappable modules for quick replacement. Each module is factory pre-calibrated to reduce setup time. However, per safety best practices, a zero and span verification is recommended after installation to ensure measurement accuracy and regulatory compliance.
⚠️ Note: "Calibration-free" operation is not advised for safety-critical gas detection. Regular validation is required by standards such as OSHA 1910.146 and GB 3836.

Q3: What output signals are available?

A: The detector includes:
Standard: RS-485 (Modbus RTU) + two independent relay outputs (programmable for alarms or control)
Optional: 4–20 mA analog output, integrated pump (for active sampling), and audible/visual alarm beacon
This ensures compatibility with PLCs, DCS, fire panels, and central monitoring systems.

Q4: What are the explosion-proof and ingress protection ratings?

A: Explosion protection: Certified to Ex d IIC T6 (or IIB T6, depending on sensor configuration) - suitable for Zone 1 / Class I Div 1 hazardous areas
Ingress protection: IP66 - fully dust-tight and protected against powerful water jets
Always refer to the product certification label for the exact rating of your unit.

Q5: In what types of environments can it operate?

A: Designed for harsh industrial conditions:
Temperature: –30°C to +65°C
Humidity: 0–95% RH (non-condensing)
It is widely deployed in confined spaces, chemical plants, oil & gas facilities, utility tunnels, and power stations-anywhere reliable, continuous gas monitoring is required.

Q6: What are the detection accuracy and response time?

A: Typical accuracy: ≤ ±3% of full scale (varies slightly by gas type and sensor technology)
Response time: T90 ≤ 30 seconds under standard conditions
Performance is temperature-compensated to maintain stability across the operating range.

 

Hot Tags: explosion proof online gas detector, China explosion proof online gas detector manufacturers, suppliers, factory, Chemical industry zirconia analyzer, Explosion proof multi gas integration detector, Hydrogen fluoride detector, In situ zirconia analyzer, online gas analyzer, PPM zirconia analyzer

Send Inquiry